最佳实验室操作规程:职业安全卫生及环境

  仪器信息网 ·  2011-03-25 20:37  ·  30159 次点击
LaboratoryBestPractices:(OH&SandtheEnvironment)最佳实验室操作规程:职业安全卫生及环境
Water
Usingwaterunnecessarilyinlaboratoriesisnotonlyawaste,itreflectspoorlyonstaffandisabadexampleforothers.Useofwaterinwateraspiratorsandforcooling(waterusedonceandruntowaste)shouldbediscontinued.
Policiesandpracticesforimmediatecleanupofwaterspillsshouldbeimplemented.
“Wetareas”shouldbeclearlyidentifiedandavoidedasapracticewhereverpossible.Permanentwetareasshouldbewellbundied.
RiskManagement:
•documentedsystemforspillsand‘wetareas’
•nowateraspiratorsusedforsuction
•nocoolingwaterruntowaste
•generalminimisationpracticed
ElectricalPower
Aregimeofelectricalmaintenance,repairandtagginginlinewithOH&SguidelinesforsafeuseisanimportantcodeofpracticeforaLaboratorytodemonstratecompliance.
Policiesandpracticesforsafehandlingofelectricalequipmentshouldbereadilyavailabletolaboratoryusers,especiallywhentheequipmentinvolvestheuseofwater.
Coal-generatedelectricityisalimitedresource.Greenhousegasesareanundesirableby-product.Wastingelectricityisamissedopportunityforgivingagoodexampletoothers.
RiskManagement:
•documentedsystemformaintenance,repair,taggingandgeneraluse
•appliancesswitchedoffwhennoinuse
•fumecupboardsturnedoffwhennotneeded
•sashesloweredonfumecupboardswherepossible
NaturalandLPGgasses
Policiesandpracticesforsafeworkingsystemsshouldbeinplacewhengasisusedinalaboratory.
WhereverLPGcontainersareused,proceduresshouldbeinplacefortheirmaintenanceandsafestorage.
NaturalgasandLPGusageisusedmainlyforheatinginbuildingsandinlaboratoriestoalesserextent.Itsuseshouldbeminimised.
RiskManagement:
•documentedsystemforsafeworkingsystemswhenusinggassesandforthehandlingandstorageofLPGcontainers
•minimalheatwastageandfuelconsumption
Chemicals,gases,biologicalagentsandradioactiveisotopes
Systeminplacetoinformusersofthepotentialhazardsanddangersofsubstancesisanecessity.
Theprovisionofclearandaccuratelabellingaofsubstancesisnecessary.
Safestorage,includingappropriatebunding,isnecessary.
MSDS’sforallhazardoussubstancesneedtobeavailableandkeptcurrent.
Accurateandappropriatesignage,meetingtheOH&SCodeofPracticeshouldbereviewed.
CompliancewiththeHazardousSubstancesRegulationandtheDangerousGoodsActisimportant.Thiswillincludeachemicals/substancesmanifestbeingavailable.Alldecisionsandoutcomesrelatingtocompliancemattersshouldbedocumented.
Laboratoriestraditionallyspendlargeamountsonchemicalsandassociatedmaterials.
SignificantamountsofchemicalsareneverusedandareeventuallydisposedofusuallyatsomecosttotheLaboratoryandtheenvironment.Sharingbottlesofreagentsandpropertrainingtominimisetheriskofcontaminationofreagentstockisanecessaryconsideration.
RiskManagement:
•documentedsystemforgeneraluseofhazardous/dangeroussubstancesegdecanting,labelling,storage,spills,bunding,andpurchasing.
•minimalchemicalsstored
•MSDSvisibletoalluser
•labellingmeetsAust.codeofPractice
•manifestsinplaceanduptodate
•safepackagingandstorage
•effectivebunding
•chemicalssourcedfromexcessstockwithintheLaboratory
•lesstoxicsubstancesusedwherepossible
Laboratory-ware
Policiesandpracticesforconsiderationwhenpurchasingandusinglaboratorywareneedtobeestablished,implemented,andmonitoredtogaugeeffectiveness.Safeworkproceduresintheassembly,andgeneraluseofapparatusisimportant.
Useofdisposablelaboratory-wareisanexpensiveoptionandnotinthebestinterestsoftheenvironment.Re-useablelaboratorywareisgenerallycheaperinthelong-termandgenerateslesswaste.
RiskManagement:
•documentedsystemforgenerallaboratorystandardsofpurchasingcontrols(quantityandtype)
•non-disposablelaboratorywareusedwherepossible
Wasteminimisation
Useofminimumquantitiesofmaterials,reuse/recyclingifpossible,andcollectionforappropriatedisposalmethodsintroducedintothelaboratoryenvironmentwillassistinaneffectiveenvironmentmanagementsystem.
Awasteriskassessmentshouldbeundertaken.Processeswhichgeneratewasteshouldbeassessedtoseekwastereductionopportunities.
RiskManagement:
•documentedwastemanagementplanestablished
•processestobeassessedandredesigningprocessestouseminimisationstrategies(processre-engineering)
RiskAssessmentoflaboratorymethods
Ariskassessmentshouldbeundertakenpriortothestartofeachsemestertodeterminelikelyriskstohealthandtheenvironment.Theseshouldbeevaluatedintermsoflikelyseverityofoutcome.Thosethatcouldtoprovehazardousintheextremeshouldbemanagedunderasystemofriskcontrol.
RiskManagement:
•riskassessmentoflaboratoryundertaken
•formalprioritisationaccordingtorisk
•controlmeasuresidentified,agreedandestablished
•monitoringbyperiodriskreview
Wastedisposal-general
Wherepracticable,hazardouswastesshouldbecollected,treatedtoreducehazardsifappropriate(eg.acidsneutralised),anddisposedofinawaythatminimisesenvironmentalimpacts.Thesepracticesshouldbedocumented.
Hazardouswastesshouldnotbetippeddownthesinkorallowedtoevaporate.
Hazardousmaterialsshouldberemovedfromobsoleteequipmentbeforedisposal.
Consumablescontainingheavymetals(eg.fluorescenttubesandNicadbatteries)shouldbesegregatedanddisposedofappropriately.
RiskManagement:
•wastemanagementplandeveloped
•acidsandalkaliscollectedandneutralised/runtotradewasteorremovedbycontractors
•nodisposalofheavymetaltotradewaste
Disposalofhazardoussubstancesdownsinks
TheEPA/CWWimposestrictlimitsontheconcentrationsofarangeofhazardoussubstancesinwaterrundownsinksandfloordrains
Inessence,nowaste(exceptwashwater)shouldberundownsinksanddrains.Wheretoxicsubstancesareinvolved,evencontaminatedwashwatermayneedtobecollectedanddisposedbycontractors(eg.washwatercontainingcyanide).
Wherecontaminationispresent,personalprotectiveequipmentsuitabletothetypeofcontaminantshouldbeavailableandusedatalltimes.
RiskManagement:
•provisionofPPEasrequiredbyMSDS
•acidsandalkaliscollectedandneutralised/runtotradewasteorremovedbycontractors
•negotiationwithEPAtoensurecompliance
Fumecupboardemissions
Protocolsfortheuseofandmaintenanceoffumecupboardsshouldbedeveloped,disseminatedandmonitored.
Fumecupboardemissionsexhaustdirectlytoatmosphereandsoshouldbeminimised.Thepossibilityofsuck-backoffumecupboardexhaustgasesintobuildingairintakes,openwindowsorthebreathingzoneofpeopleworkingontherooforinotherbuildingsshouldbeinvestigated.
Modificationssuchasclosed-cyclewaterscrubbersorextensionofexhaustductsshouldbeconsideredwherenecessarytominimisehealthorenvironmentalrisks.
FumecupboardsareacomplianceissueintermsofriskmanagementbothtotheenvironmentandasanOH&Sissue.Thereforedecisionsrelatingtothemanagementandchangesintheuseoffumecupboardsshouldbedocumentedandrecordsshouldbekept.
RiskManagement:
•worktowardcompliancewithappropriatestandards.
•greenhouseemissionminimised
•minimalvapour/gasesemittedintocupboards;usecoldtrapsifpossible
Laboratoryairquality
Thequalityoflaboratoryairshouldbemonitoredconsideringchemicalgasesandvapourcontamination,aswellasnoise,vibration,dustsetc.
Workwhichmaypotentiallycontaminatelaboratoryairshouldbemovedtofumecupboards.
Unusedgascylindersshouldberemovedfromlaboratories.
RiskManagement:
•eliminatemercuryusewherepossible,otherwisetestformercuryvapour
•allnecessaryworkconductedinfumecupboards
•disposeofallunusedcylindersoftoxicgas
•oilmistfiltersonvacuumpumps
CFCandHCFC(hydrochlorofluorocarbon)use
Anynon-essentialuseofCFCsandotherozone-depletingsubstancesinthelaboratoryshouldbediscontinued.
HCFCs(alsoozone-depleting)shouldbephasedoutwheresubstitutesexist.
RiskManagement:
•reviewuseofCFC’sandeliminatewherepossible
•reviewuseofHCFCandeliminatewherepossible
Hazardousvapoursdrawnintotradewastebywateraspirators
Wateraspiratorsthatdrawtoxicvapoursintowaterflowingdownthesinkmayleadtononcompliancewithtradewasteregulations.Suchvapoursshouldbetrapped(andreusedifpossible).Theuseofwateraspiratorsformorethanshortperiodsoftimeshouldalsobeavoided(wasteofwater).
RiskManagement:
•worktowardeliminationofallwateraspirators
Riskofunintendeddischargestotradewaste
Allrisksofunintendeddischargetotradewaste(eg.chemicalspills)shouldbeassessed.Significantrisksshouldbeaddressedbyestablishingoperationcontrols(eg,spilltrays)tominimisethelikelihoodandmagnitudeofsuchdischarges,bydrawingupcontingencyplans,andbyhavingequipmentsuchasspillkitsavailable.
RiskManagement:
•reviewanddocumentprocessestominimiseriskofunintendeddischargestotradewaste
•blockofffloordrainswherepracticable
•bundingandcontainmentofstorageareas
pHControloftradewaste
TradewasteregulationsrequirealldischargestotradewastetobebetweenpH6–10.Concentratedacid,dilutedonemilliontoonewithwater,maystillbebelowpH6.Acidwastecancauselong-termdamagetosewersandcangenerategasesharmfultomaintenanceworkersinthesewers.Allwasteacidandalkalishouldbecollectedandneutralised(andcanbetippeddownthesinkonlyiftherearenohazardoussubstancespresent).
RiskManagement:
•eliminatealldisposalofacidsandalkalistotradewaste
Licensesandpermits-toxicchemicalsorbiologicalsubstances
LaboratorypersonnelshouldbeawareofandmaintainalllicencesandpermitsheldbytheDepartment/Laboratorywhichapplytochemicalorbiologicalsubstancestheyareusing.
Theyshouldbeawareofallconditionsoftheselicences/permitsandcomplywiththem.
RiskManagement:
•Ensurecompliancewithlegislationgoverningchemicalandbiologicalsubstanceseg.Drugs,Poisons&ControlledSubstancesAct.
Licensingofirradiatingapparatusandradioactivesources
LaboratorypersonnelshouldbeawareofandmaintainalllicencesforirradiatingapparatusandradioactivesubstancesheldbytheDepartment/Laboratorywhichapplytotheworktheyareundertaking.
Theyshouldbeawareofallconditionsoftheselicencesandcomplywiththem.
RiskManagement:
•ensurelegislativecompliance
Bunding-general
Allcontainersofhazardousliquid(includingwastes)shouldbebundedsuchthatleakageofthefullcontentsofthelargestcontainerofliquidinthebund/traywillbecontained.
Corrosiveliquidsshouldnotbestoredinmetaltrays.
RiskManagement:
•riskassessmentundertakentoestablishtheneedforbunding
•theneedfor,andeffectivenessofbundingreviewperiodically
Transport
Adequatesafetyequipmentshouldbeavailableandusedbypersonneltransportinghazardoussubstances.
Allpersonnelusingsuchequipmentmustbetrainedwhenandhowtouseit,andhowtorespondtoaspill.
RiskManagement:
•riskassessmentundertakentoestablishtheneedforpersonalprotectiveequipment
•spillresponseproceduredocumentedandcommunicatedtopersonneltransportinghazardoussubstances
Spillkits
Spillkitsmustbesuitableandadequateforanyforeseeablespillinthelaboratory.
Thekitsshouldbeclearlylabelled,inalocationknowntoallpersonnel,andallpersonnelshouldbetrainedintheiruse.
RiskManagement:
•spillkitsprovidedinstrategicpositions
•inductionintolaboratorytoincludeuseofspillkits
Back-flowpreventioneg.,“townwater”supply
Backflowisthecontaminationof“town-water”withtradewaste.Thiscouldhappenviaplastichoseshangingfromtapsintoasink.eg,whenwaterpressureislost,contaminatedwaterfromasinkmaysiphonupandintothewatermains;or,themigration(growth)ofalgae–whichmaybeharmfultopeople–fromthesink,intoacoolingwaterhoselyinginthesink.
RiskManagement:
•worktowardeliminationallcouplingsbetweentownwaterandwastewater
•educatelaboratorystaffontheneedforbackflowprevention
Standardofsafetyandenvironmentalperformanceofcontractorsworkinginthelaboratory
AllcontractorsworkinginalaboratoryshouldbebriefedonappropriateLaboratorystandardsandprocedures,andtheirworkmonitoredforcompliancewiththosestandardsandprocedures.
Thereshouldbeaformalagreementtomeetstandardsandcodesofpractice.
RiskManagement:
•contractorobligationsclearlystatedintenders,purchaseordersetc
•performanceofcontractorsmonitoredthroughouttheperiodofthecontract
AnyfieldworkiscarriedoutinaccordancewithLaboratoryguidelines
TheLaboratoryshallprepareguidelinesforfieldwork.
Laboratorystaffworkinginthefieldshouldbecompetentintheuseoftheseguidelinesandworkinaccordancewiththem.
RiskManagement:
•guidelinesinplace
•guidelinesincludedininductionprocessasnecessary
Training
Alllaboratorypersonnelwithlaboratoryresponsibilities(ieallpersonnel)shouldbetrainedintheperformanceoftheirresponsibilities.Thecompetenceofpersonnelwithkeyresponsibilities(eg.transportofwaste,leadingemergencyresponse)shouldbetestedtoensuretraining/experienceisadequate.Allpersonnelshouldbeawareofenvironmentallegalobligationsapplicabletotheirwork.
RiskManagement:
•clearlinesofauthorityandresponsibilitydocumented
•trainingprovidedandperformanceoutcomesmonitored
•documentedsystemsinplaceforongoingtrainingneedsidentificationandactioned
Communication,documentationandrecords
Aformalsystemforreportinghazardsandincidentsshouldbeinplace,andalllaboratorypersonnelshouldbefamiliarwithit.Aprocessforinvestigatingincidents,reportingfindingsandactingonthemshouldbeinplace.
Systemsfordocumentcontrolandrecordsmanagementshouldalsobeestablished.
Recordsshouldbeavailabletoallpersonnelwhoneedtousethem.
RiskManagement:
•allprocessesrequiringcontrolstobedocumented
•inductionofstaffandothersundertakenasrequired
•recordsmanagementsystemdefinedandimplemented
Operationalcontrol&emergencyresponse
Thereshouldbeaformalprocessfortheevacuationofthelaboratoryinanemergencysituation.
ThisshouldincludeamechanismforreportingtheemergencytothewiderLaboratorycommunityandfollowuptopreventoccurrence.
Foreseeable“loss-of-control”situationsshouldbeidentifiedandassessed,andoperationcontrolsputinplacetopreventloss-of-control.
RiskManagement:
•riskassessmentundertaken
•laboratoryemergencyresponseplandevelopedinlinewiththe
Laboratoryplan
Auditandreviewoflaboratorymanagementsystemsandtheireffectiveness
Anaudit/reviewprogramshouldbeestablishedandmanaged.
.AperiodicdepartmentalmanagementreviewshouldreviewOH&SandenvironmentalperformanceandtheeffectivenessofthesystemasaprovideroflaboratoryservicestotheLaboratorycommunity.
RiskManagement:
•auditscheduledeveloped
•auditsundertaken
•auditsactionedappropriately
•outcomesperiodicallyreviewedbystakeholdersforsystemsmonitoringpurposes
最佳实验室操作规程:职业安全卫生及环境

实验室里不必使用的水不仅是废物,它还能给工作人员带来负面影响。吸水器中的水和降温用水(一次性使用水并排放为废物)应该丢弃掉。
应该实行有关规章制度,立即处理洒溢出来的水。应该清楚地界定“潮湿区域”,并尽可能避免出现这种情况。对长期潮湿的地方要用隔离出来。
风险管理
•洒溢和潮湿区域的文档管理系统
•抽水泵不使用吸水器
•没有制冷的水排污
•通用最小化规程
电源
符合职业安全卫生制度的电源维护、保修等内容是实验室规程的重要法规。
应该为实验室人员准备电子设备的安全操作规程和制度,特别是那些用水设备。
煤电是种有限的资源,温室气体是多余的副产品,因此浪费电力资源是不好的行为。
风险管理
•对其保养、维修、标签和其它应用进行文档记录
•不使用的时候应该关闭应用器具
•不用通风橱时要把它关闭
•通风橱的窗扇要尽可能的降低
天然气和液化气
当实验室应用天然气的时候,应该配有相应的安全工作制度和规程。
当使用液化气罐的时候,应该制订出相应的维护和安全制度。
天然气和液化气的使用可以减少建筑物和实验室的采暖要求,但要尽量减少应用它们的机会。
风险管理
•当应用天然气、并处理和储存液化气罐时,要建立安全操作的文档管理体系。
•把热能浪费和燃料消耗降到最低限度
化学品、气体、生物制剂和放射性同位素
有必要配备物品潜在危险性的警示系统。
每个物品必须贴有清晰、正确的标签。
必须安全储存物品,适当的情况下要采用隔离措施。
要准备所有危险品的物料安全数据表并保持其时效性。
应该审核签名是否正确并符合职业安全卫生法规的规程。
遵守危险品法规和危险物料法令的管理是十分重要的,其中涉及已有的化学品和物品。所有与法规事务有关的决定和结果应该存档。
实验室一般在化学品和相关物资的采购上花费很大。
绝大多数化学品从未用过,最后通常都被处理掉,这给实验室和环境都增加了成本负担。必须考虑到,共享制剂和适当的培训能最大限度地降低试剂库存受污染的危险。
风险管理
•危险物品的使用(如倾倒移液,标签,储藏,防洒溅,隔离和购入)的文档管理系统。
•化学品的库存量保持最低
•所有用户都可以查看物料安全数据表
•标签符合国家法规的规定
•备有库存单,且在有效期内
•安全包装和储藏
•有效的隔离措施
•实验室内多余的库存化学品
•尽可能减少有毒物质的使用
实验室器皿
需要建立、实施并监控采购和使用实验室器皿的规章制度。装配线的安全工作流程和设备的充分利用是非常重要的。
使用废弃实验室器皿的成本是昂贵的,同时也不符合环保要求。从长远角度看,实验室器皿的重复利用并尽量减少废物的生成,可以大幅度降低成本。
风险管理
•一般实验室采购管理标准的文档系统,其中涉及物品的质量和型号。
•尽可能使用不需弃置的实验室器皿
降低废物的产生
在可能的情况下尽量减少物料的使用,或者重复、循环利用物料;为实验室引入适宜的废物处理方法,这样对环境的管理能起到帮助作用。
应该对废物进行风险评估。生成废物的过程要经过评估以降低其产生量。
风险管理:
•为废物管理计划建立档案机制
•对流程进行评估甚至重新设计,以满足最小(少)化的方针。
实验室方法的风险评估
应该根据后果的严重性,对实验方法于健康和环境可能产生的有害影响进行风险评估。被证明具有极度危险性的,应该在风险控制体制下得到管理。
风险管理
•实验室实行风险评估
•根据风险制订正式的优先管理项目
•控制措施的鉴别、确定和建立
•定期进行风险审核
一般废物的处理
根据实际情况,收集并处理危险废物以降低其危险性,比如酸的中和;处理时要用能最大限度降低对环境造成影响的方法。
不能把危险废物倾倒在水池内或者任其蒸发。
危险品在处置前应该远离已被荒废的设备
应该隔离含重金属的消耗品(如荧光管和镍镉蓄电池),并用适宜的方法处置。
风险管理
•废物管理计划的开展
•收集并中和酸碱物质或者由工作人员搬移。
•不得废弃含重金属的废物
处理到水槽中的危险品
国家环保局对倒入水槽和地下水道的危险品的浓度范围有严格限制。
除了清洗用水,废物一般不能倒入水槽和下水道。当物品有毒时,甚至受污染的清洗用水也需要收集起来并统一由工作人员负责处理(如含氰化物的清洗用水)。
有污染情况出现时,应该备有随时可以使用的相应的个人保护装置。
风险管理
•提供物料安全数据表中要求的个人防护装备。
•收集并中和酸碱,或者由工作人员搬移。
•与国家环保局加强联系,确保各项操作符合有关规定。
通风橱的气体排放
应该执行通风橱的使用和保养草案
通风橱排出的气体直接排放至大气中,排量应该控制到最低限度。应该调查通风橱废气回吸至房屋内的进风口、打开的窗户或者房顶工作人员的呼吸区域或者其它房屋的可能性。
必要的地方,应该考虑更换封闭式循环冲洗物或者延长废气排放管,以降低对健康或环境的危害。
环境和职业安全卫生法规中的风险管理,有对通风橱的管理条款。所以使用通风橱时,与管理和变更有关的决定应该被存档并保留记录。
风险管理
•符合相关标准的工作
•最大限度降低温室气体的排放
•最小限度的通风橱蒸汽/气体排放;如果可能使用冷水闸。
实验室空气质量
应该监控实验室空气质量,涉及对化学气体和蒸汽污染,以及噪音、震动和灰尘等的监控。
可能会污染实验室空气的工作应该移至通风橱。未使用过的气罐应该从实验室移走。
风险管理
•尽可能不使用水银,否则要检测是否有水银蒸汽。
•所有在通风橱中进行的必要工作
•所有废用毒气缸的处置
•真空吸泵中的油雾过滤
氯氟碳和氢氯氟碳的使用
应该放弃任何CFC的不重要应用和实验室中的其它臭氧祛除剂。
在有替代品的时候,应该逐渐淘汰HCFC(即臭氧祛除剂)。
风险管理
•可能的情况下,CFC的重复使用和排除
•可能的情况下,HCFC的重复使用和排除
吸水器产生的成为商业废物的危险蒸汽
把吸水器中的有毒蒸汽随水流排入水槽是违反商业废物法规的。这类蒸汽应该集中处理(可能的情况下重复利用),也应该避免吸水器的长期应用(这样可以避免产生废水)。
风险管理
•所有吸水器排除的工作
非有意识性废物排放的风险
应该评估所有无意识的废物排放(如:化学品的溢出)。应该通过建立操作控制(如洒溅盘),起草应急方案并置备像防洒溅这样的设备来处理重大风险,以便最大限度降低这些排放的可能性和数量。
风险管理
•建立评审和归档流程,以最大限度降低商业废物无意识排放的风险。
•在可以的地方堵住地下水道
•储存区域的隔离
商业废物酸碱值的控制
商业废物规定中要求所有排放的商业废物的酸碱值在6-10之间。浓缩的酸,用水稀释成100万比1的浓度,仍可以使pH值为6。酸废物能长期腐蚀下水道,并能产生伤害水暖工的气体。所有废弃的酸碱应该收集并中和(只有不存在危险物质后才能冲入水槽)。
风险管理
•排除所有对酸碱性废物的处置
有毒化学品或者生物品的许可证和执照
实验室人员应该知道并维护部门和实验室持有的所有应用化学及生物制品的执照和许可证。他们应该知道所有执照/许可证的作用并遵守相应的规定。
风险管理
•保证符合管制性化学和生物制品的法规,如药品,毒品和控制品法令。
一般性隔离措施
应该隔离所有盛装危险液体(包括废料)的容器,这样即使最大液体容器中内容物全部泄漏也会被盛装起来。
风险管理
•对隔离装置的设置开展风险评估
•定期检查隔离设施的需求和有效性
运输
运输危险品的人员应该配备并应用充足的安全设备
所有应用这种设备的人员必须接受培训,知道在何时、如何应用它们,以及如何对溢出物做出快速反应。
风险管理
•对建立个人保护装置的需求开展风险评估
•为备有危险品运输的文件,说明洒溅事件的处理流程。
防洒溅装置
防洒溢装置必须适合任何实验室内不可预见性的洒溢事故。
该装置应该有清晰的标签,放在所有人员都知道的位置,并且所有人员应该就其使用方法接受培训。
风险管理
•为重要岗位提供防洒溢装置。
•为实验室引入防洒溢装置。
逆流的防范,如“城市水”的提供
逆流是指受商业废物污染的“城市用水”。发生这种情况是因为,自来水管中的水通过塑料软管被引到水槽里。比方说,当水压不足时,水槽中受污染的水可能会虹吸上来倒灌至主水流干线,或者对人类可能有害的藻类迁徙(生长)到水槽中的冷水软管内。
风险管理
•排除所有城市用水和废水的连接
•教育实验室工作人员防范发生逆流。
实验室工作人员的安全和环境操作标准
所有在实验室工作的人员应该总结实验室的标准和规程,及其与那些标准和规程相符的工作。
应该有正式的协议满足行业标准和法规。
风险管理
•工作人员的义务应该在标书、采购单中清楚地规定出来。
•工作人员的表现在整个任职期间都能得到监控。
根据实验室方针执行任何场地工作
实验室应该为场地工作制订规则。
在场地工作的实验室人员应该能胜任这些方针和与之有关的工作。
风险管理
•适当的方针
•必要的归纳过程
Training培训
所有担负有一定职责的实验室人员应该接受操作职责的培训。应该检测关键性岗位人员的技能(如废料运输,紧急泄漏事故的反应)以保证他们能接受足够的培训并具有一定经验。所有人员都应该了解应用于工作中的法定性环境职责。
风险管理
•在归档的有关权限和职责文件中有清晰的文字说明。
•提供的培训和受控的业绩成果
•为培训需求的界定和执行备有归档体制
沟通、文档和记录
应该有报告危险和意外事故的正式机制,所有实验室人员应该对之非常熟悉。应该具有调查意外事件、汇报所发现的内容以及采取措施的规程。
还应该建立文档控制和记录管理的机制。所有需要应用的人员都应该能够查看记录。
风险管理
•所有需要控制的流程都要归档
•人员和其它事务的归纳
•制定和执行的记录管理体系
Operationalcontrol&emergencyresponse
在实验室发生紧急事件的情况下的正式撤离流程(文档)。
应该有给更大的实验室团体汇报紧急情况并随后总结防范类似事件的再次发生的机制。
应该鉴别和评估可预见性的“失控”情况,应该有操作监控机制以防止出现失控现象。
风险管理
•采用风险评估
•在符合实验室计划的前提下,开展实验室紧急事件响应计划。
Auditandreviewoflaboratorymanagementsystemsandtheireffectiveness
应该建立并管理审计/审查规划(程序)
定期的部门管理审查应该检查“职业安全卫生”和环境操作,及为实验室及其整个团体提供服务的系统的有效性。
风险管理
•开展的审计计划
•采用的审计
•合理执行的审计
•为了监控系统,财物保管员定期审查成果。

0 条回复

暂无讨论,说说你的看法吧!

 回复

你需要  登录  或  注册  后参与讨论!